WhatsApp : +88 01818929292 / +8801730296909
info@smmarineservice.com sohelbhuiyan1213@gmail.com
WhatsApp : +88 01818929292 / +8801730296909
info@smmarineservice.com sohelbhuiyan1213@gmail.com
Product Image Product Image
Product Image
Product Image

DECKMA HAMBURG OMD-24 15 ppm Bilge Alarm / Oil Content Meter – Refurbished

Item Code:

OMD-24

Brand:

DECKMA HAMBURG

Condition:

Refurbished


DECKMA HAMBURG OMD-24 15 ppm Bilge Alarm / Oil Content Meter – Refurbished

Product Information

Product Name DECKMA HAMBURG OMD-24 15 ppm Bilge Alarm (Oil Content Meter / Oil-in-Water Monitor)
Manufacturer DECKMA HAMBURG GmbH, Germany
Model / Type OMD-24 (as shown on the nameplate)
Art. No. (nameplate) Partly readable as 79100/1212 – Not verified
Serial No. (nameplate) 2004099
Year (nameplate) 2012
Voltage (nameplate) 24 V AC/DC
Measuring Cell Label 4001603 (as visible on the cell label)
Supplied As Computer Unit and Measuring Cell mounted on a stainless back plate, with interconnecting cable
Country of Manufacture Germany (manufacturer address on the nameplate: Hamburg)
Condition Refurbished / Used
Supplier SM MARINE SERVICE™, Chattogram, Bangladesh – worldwide shipping

Product Introduction

The DECKMA HAMBURG OMD-24 is a 15 ppm bilge alarm, also known as an oil content meter or oil-in-water monitor, used with the oily water separator (OWS) on board ships. It continuously measures the oil content of the treated bilge water before it is discharged overboard and gives an alarm and control signal if the oil content reaches the set limit. SM MARINE SERVICE™ (https://www.smmarineservice.com/) supplies refurbished OMD-24 units, measuring cells and related spare parts to ship owners, ship managers and repair companies worldwide.

What Is This Equipment?

Under MARPOL Annex I, bilge water with an oil content above 15 ppm must not be discharged into the sea. The OMD-24 was designed by DECKMA HAMBURG GmbH for use together with 15 ppm oil-water separators and meets IMO Resolution MEPC.107(49). The system is made of two main parts: the Computer Unit, which shows the ppm reading, handles alarms, data logging and external connections, and the factory-calibrated Measuring Cell, which measures the oil content of the sample water using an optical (scattered light) method. Because the calibration is held in the Measuring Cell, the OMD-24 Series is designed so that only the Measuring Cell needs to be exchanged for re-calibration.

Main Features

  • 15 ppm bilge alarm according to IMO MEPC.107(49); U.S. Coast Guard approved model
  • Measuring range 0–30 ppm with trend indication up to 50 ppm
  • Two alarm set points (AL1 and AL2), adjustable between 1 and 15 ppm, works-set at 15 ppm
  • Graphic display with ESC, +, –, OK, TEST, SET and LOG keys and ON / AL1 / AL2 / SYS indicator LEDs
  • Built-in data logger with DECKMA memory card
  • Potential-free alarm relays for the OWS overboard valve / automatic stopping device
  • Optional 0(4)–20 mA output for a recorder or external meter
  • 24 V AC or DC supply, low power consumption, IP65 protection
  • Variants: OMD-24, OMD-24 EV (electric valve), OMD-24 EVA (electric valve + auto clean), OMD-24 A (auto clean) and OMD-24 FC (flow control)

DECKMA HAMBURG OMD-24 15 ppm bilge alarm oil content meter refurbished - SM MARINE SERVICE
DECKMA HAMBURG OMD-24 15 ppm Bilge Alarm – Computer Unit and Measuring Cell on back plate (refurbished, SM MARINE SERVICE™ stock photo)

Main Technical Specifications

Measuring Range 0–30 ppm, trend indication up to 50 ppm
Accuracy According to IMO MEPC.107(49); linearity better than ±2 % up to 30 ppm
Display Graphic display
Power Supply 24 V AC or DC ±10 %
Power Consumption < 5 VA (standard OMD-24)
Alarm Points 1 + 2 Adjustable 1–15 ppm (works setting 15 ppm)
Alarm 1 Delay 1–540 s (works setting 2 s)
Alarm 2 Delay 1–10 s (works setting 10 s)
Alarm Relays Potential-free, 1-pole changeover, 3 A / 240 V
Analog Output 0(4)–20 mA (equal to 0–30 ppm), optional
Sample Water Temperature +1 to +65 °C
Ambient Temperature +1 to +55 °C
Sample Pressure 0–10 bar (standard OMD-24)
Sample Flow Approx. 0.1–3 l/min (standard OMD-24)
Pipe Connections R 1/4" female
Protection IP65
Computer Unit Size 185 × 210 × 65 mm
Weight Approx. 2.5 kg

Specifications are from published DECKMA OMD-24 documentation; please confirm against the nameplate of your unit.

Inside the Unit: PCBs, Modules & Part Numbers

Ship engineers often search only by a part or article number when one module of the bilge alarm fails. Below are the modules and DECKMA article numbers we found in published OMD-24 documentation. Please send us your nameplate and part label photo so we can match the exact item.

Computer Unit with Display PCB and Data Logger

The Computer Unit contains the display PCB with the data logger and the terminals for external connections (power, alarm relays, 0/4–20 mA output, remote inputs). A separate article number for the display PCB / main PCB was not found in public documentation – Not verified. Nameplate on this unit: Type OMD-24, Ser. No. 2004099.

Measuring Cell – Art. No. 77500

The factory-calibrated optical sensor that measures the oil content in the sample glass tube. It stores the calibration and is the part exchanged at calibration renewal.

Service Exchange Measuring Cell – Art. No. 2277500

Exchange measuring cell including new calibration, used to keep the bilge alarm within its calibration validity.

Memory Card – Art. No. 79186

DECKMA memory card used by the data logger to record ppm readings, alarms and status.

Sensor PCB – Art. No. 56300 (Flow Conversion Kit)

Electronic board for the flow sensor in the OMD-24 FC flow-control version, used together with Flow Sensor 16700 and Y-Cable 56810.

Auto Clean Controller Assembly – Art. No. 78790

Control assembly for the automatic cell cleaning on OMD-24 A and OMD-24 EVA versions.

Auto Clean Actuator Assembly – Art. No. 78780

Pneumatic actuator that drives the wiper through the sample glass tube (A / EVA versions).

Electric Valve – Art. No. 13215

Electrically operated valve for switching between sample water and fresh water on OMD-24 EV / EVA versions.

Other Spare Parts and Article Numbers

Desiccator 79550
Cell Cleaning Brush 77555
O-Ring Set 77775 (OMD-24, EV) / 77773 (A, EVA)
Push-In Fitting PVC 79412 / 79421
T-Piece PVC 79415 / 79422
Wiper Seal 77606
Wiper, complete with Wiper Seal 77792
Service Kit 18570
Air Pressure Filter / Regulator Unit 16270
Set of Push-In Connectors and Hoses 78770
Pneumatic Cylinder 78785
Solenoid Support 79019
Conversion Kit to OMD-24 FC 56250
Flow Sensor 16700
Y-Cable 56810
Flow Laminator Pipe (100 mm) 56420
Manual Cleaning Unit (MCU) 77780
OMD-CR Memory Card Reader 75185
Calibration Check Kit 18515

Main Components & Related Units

  • OMD-24 Computer Unit – display, keypad, alarms, data logger, terminals
  • OMD-24 Measuring Cell (77500) – calibrated optical sensor with sample glass tube
  • Cleaning device – the cell in this photo is fitted with a lever-type cleaning attachment (exact type not verified)
  • OMD-24 EV / EVA / A / FC versions – electric valve, auto clean and flow control arrangements
  • Related DECKMA models – OMD-2005, OMD-2008, OMD-2008 EV and OMD-32 oil content meters

Marine & Industrial Applications

  • 15 ppm bilge alarm for oily water separators on cargo ships, tankers, bulk carriers and container vessels
  • Offshore support vessels, ferries, cruise ships, naval and government vessels
  • Control of the overboard discharge valve / automatic stopping device of the OWS
  • Recording of oil content data for MARPOL compliance and Port State Control inspections
  • Oil-in-water monitoring in cooling water and condensate lines (with suitable set points)

DECKMA OMD-24 bilge alarm measuring cell and computer unit spare - SM MARINE SERVICE worldwide supplier
OMD-24 Measuring Cell with cleaning lever, Computer Unit with keypad and nameplate – available from SM MARINE SERVICE™

Common Problems & Troubleshooting

Safety note: Isolate the 24 V supply before working on wiring. Close the sample and fresh water valves and release pressure before removing the cell cap. Do not open or dismantle the Measuring Cell – the manufacturer warns this may void calibration and certification. Never bypass the bilge alarm or overboard valve.

  • High ppm reading with clean water – the sample glass tube is dirty (oil film, iron oxide). Clean it with the cell cleaning brush through the cell cap; for iron oxide, citric acid cleaner can be used. Clean water should read 0 ±2 ppm.
  • No sample / unstable reading – check the sample flow, air in the line, closed valves or a blocked sample line.
  • No communication between Computer Unit and Measuring Cell – check the interconnecting cable and connectors.
  • Humidity / desiccator warning – check and replace the desiccator (79550).
  • Data logger warning – check that the correct DECKMA memory card is inserted and activated.
  • Calibration expired – exchange the Measuring Cell or replace the complete calibrated unit.

Common Alarms

Status messages documented in the OMD-24 Series manual include:

  • FW! – fresh water mode is active or the remote fresh water input is linked
  • Flow! – sample flow too low or no flow (flow-control versions)
  • EVALVE? – electric valve position not detected (EV units)
  • Com? – no communication between Computer Unit and Measuring Cell
  • Sample? – sample cannot be measured (no water, very high oil content or no light transmission)
  • Data log? – memory card missing, read-only or not activated
  • Int.Err – internal error; restart the system
  • Desicc. – humidity in the Measuring Cell too high; check the desiccator

Maintenance Tips

  • Weekly: visually check for leaks, damage and cable condition
  • Weekly: check the desiccator humidity via the SYS key and replace the desiccator when needed
  • Weekly: flush with clean water and confirm a reading of 0–2 ppm
  • Clean the sample glass tube with the cell cleaning brush; avoid abrasive cleaners
  • Use the TEST function only when the oil content is below 15 ppm
  • Check that the data logger is recording and the clock is correct
  • Protect the cell from freezing by draining it completely
  • Keep a service kit (18570), spare desiccator and O-ring set on board

Spare Parts & Replacement Availability

SM MARINE SERVICE™ supplies the DECKMA OMD-24 bilge alarm as a complete unit and can also source the Computer Unit, Measuring Cell and the spare parts listed above, subject to availability. For a fast quotation, please send:

  • A photo of the nameplate (Type, Art. No., Ser. No., year)
  • A photo of the Measuring Cell label
  • The version you use (OMD-24, EV, EVA, A or FC)
  • The vessel name and delivery port

We ship worldwide by courier and air freight.

Why This Equipment Is Still Used

The OMD-24 is one of the most widely installed 15 ppm bilge alarms and is fitted by many oily water separator manufacturers. Its modular design – Computer Unit plus exchangeable calibrated Measuring Cell – makes it simple to keep in service. Many ship owners prefer a like-for-like replacement because it fits the existing wiring, piping and OWS control without modification.

FAQ

1. What is the DECKMA OMD-24?
It is a 15 ppm bilge alarm (oil content meter) used with the oily water separator to monitor overboard discharge.

2. What is the measuring range of the OMD-24?
0–30 ppm, with trend indication up to 50 ppm.

3. What power supply does it need?
24 V AC or DC ±10 %.

4. What is the article number of the OMD-24 Measuring Cell?
Measuring Cell 77500; Service Exchange Measuring Cell with new calibration 2277500.

5. Do you have the display PCB of the OMD-24 Computer Unit?
The display PCB is part of the Computer Unit. Send us the nameplate photo and we will check a complete Computer Unit or board for you.

6. What is Sensor PCB 56300?
It is the sensor board of the flow conversion kit used on the OMD-24 FC version.

7. What is the memory card number for the OMD-24 data logger?
DECKMA memory card 79186; card reader OMD-CR 75185.

8. What is the OMD-24 service kit number?
Service kit 18570 (desiccator, O-ring sets, cleaning brushes, cleaner).

9. Why does my OMD-24 show a high reading with clean water?
Usually the sample glass tube is dirty. Clean it as described in the manual and check again with clean water.

10. Is the OMD-24 IMO approved?
Yes, the model is designed to meet IMO Resolution MEPC.107(49) and holds U.S. Coast Guard approval.

11. Can the OMD-24 replace an OMD-2005 or OMD-2008?
Replacement depends on wiring and piping; send us your existing nameplate and we will advise.

12. Do you ship worldwide?
Yes, SM MARINE SERVICE™ ships to ports and ship managers worldwide.

Short Product Description

Refurbished DECKMA HAMBURG OMD-24 15 ppm bilge alarm / oil content meter, supplied by SM MARINE SERVICE™. The unit consists of the OMD-24 Computer Unit with graphic display, keypad, two adjustable alarm set points and data logger, and the calibrated Measuring Cell mounted on a stainless back plate with interconnecting cable. It operates on 24 V AC/DC and measures 0–30 ppm in line with IMO MEPC.107(49). Nameplate: Type OMD-24, Ser. No. 2004099, year 2012. Suitable as a like-for-like replacement for oily water separator monitoring on ships. Measuring cells, memory cards, desiccators, O-ring sets and other OMD-24 spare parts can also be sourced. Worldwide shipping available.

SM MARINE SERVICE™ – Marine Automation & Navigation Equipment Supplier

Available Equipment Conditions: New • Used • Refurbished • Reconditioned (Specific product condition and availability are subject to confirmation.)
Stock Locations: Bangladesh • China
Services: Worldwide Shipping • Technical Support • Spare Parts Supply • Marine Equipment Sourcing
Samir Market, DT Road, Pahartali, beside CDA Market, Chattogram, Bangladesh
Mobile / WhatsApp / Viber: +88 01818 929292
Email: info@smmarineservice.com
Website: https://www.smmarineservice.com/

Need a DECKMA OMD-24 bilge alarm, measuring cell or spare part? Send us your nameplate photo today for a fast quotation.


Related products

Seres ODME MK III Oil Discharge Monitoring Equipment Control Unit

BDT 0

Seres ODME MK III Oil Discharge Monitoring Equipment Control Unit

BDT 0

Seres ODME MK III Oil Discharge Monitoring Equipment Control Unit

BDT 0

KONGSBERG GT404D4H25T Pressure Transmitter | GT404 25 Bar Marine Cargo Line & Manifold Pressure Sensor

BDT 0

SM Marine Service

SM Marine Service

Marine Equipment Supplier

Welcome to SM Marine Service! How can we help you today? 8:45 AM
Need Help? Chat with us