M35190
Honeywell
Refurbished
| Brand | Honeywell Marine |
|---|---|
| Model on nameplate | EM540V3 |
| Part marking | M35190 |
| Release marking | 00 |
| Product type | Marine radar tank level gauge |
| Nameplate company location | Bourges, France |
| Condition | Refurbished |
The EM540 is part of Honeywell Marine’s fixed tank gauging range. The top-mounted radar measures the distance to the liquid surface without a probe immersed in the cargo. The vessel’s gauging system uses the measured distance and the configured tank reference to report the liquid level.
The radar is one component in the vessel’s gauging installation. When replacing an existing transmitter, check the interface to the installed central unit as well as the tank-specific configuration. A matching model name alone does not establish interchangeability.
| Ingress protection marking | IP66/67 |
|---|---|
| Intrinsic safety entity limits on photographed nameplate | Ui 65 V, Ii 50 mA, Pi 0.60 W |
| Mechanical features visible in the photo | Circular flange with bolt holes, enclosed head, and three external fittings |
The Ui, Ii and Pi values are entity limits printed on the label. Obtain the applicable equipment certificate, control drawing and vessel wiring documents to determine supply and barrier requirements for the installation.
The photographed assembly has a circular flange and an enclosed head. Compare the bolt pattern, mounting interface and external fittings against the existing unit and vessel drawing. The supplied views show the outside of the assembly, so identify any required internal board, gland, seal or connector by its own marking and the applicable Honeywell parts list.
Honeywell documents the EM540 for marine tank gauging. On a vessel equipped with the corresponding Honeywell installation, the transmitter provides a tank level measurement for the gauging system. Verify the tank service and installation requirements using the vessel drawings before selecting a replacement.
For a missing or unstable level reading, have a qualified technician check the gauging system diagnostics, the affected tank channel and the installed documentation before attributing the issue to the transmitter. Ask the vessel team for the displayed fault, the last known reading and whether adjacent tanks are affected.
For work on the housing, glands or wiring, follow the applicable Honeywell installation and maintenance instructions, the certificate conditions and the vessel’s hazardous-area procedures.
Send a clear photo of the installed gauge nameplate, model, part marking, release, flange dimensions, connector views and the relevant tank or system drawing. Include the requested quantity and your delivery city and country. Confirm configuration, certificate applicability and system interface with the vessel’s technical team before ordering.
Honeywell EM540 Marine Radar Level Gauge datasheet (PDF). The datasheet identifies MT5016 as the technical manual, MI5016 as the installation manual and MM5016 as the maintenance manual. Use the applicable revision for the vessel.
What item is offered? A refurbished Honeywell Marine EM540V3 radar level gauge marked M35190, release 00.
Can it replace any EM540? Compare the release, mounting interface, wiring, gauging system configuration and applicable approval documentation before selecting it.
How can I request a quotation? Email the nameplate photo, tank or system details, quantity and destination to info@smmarineservice.com.
SM MARINE SERVICE™
DT Road, Pahartali, Chattogram, Bangladesh
WhatsApp: +8801818929292 / +8801730296909
www.smmarineservice.com
0
Marine Equipment Supplier