FOCAS-1800
Fellow Kogyo
Refurbished
| Manufacturer | Fellow Kogyo Co., Ltd. (Tokyo, Japan) |
| Model | FOCAS-1800 |
| Product Type | 15ppm Bilge Alarm / Oil Content Monitor (oil concentration detector) |
| Japanese Type Approval No. | M-248 |
| USCG Approval No. | 162.050/9039/0 |
| EC (MED) Approval | MED-B-3039 |
| Korea Approval | BAM-5 |
| China Approval | DB05T00016 |
| Canada Approval | CBA-015 |
| Serial No. | X1869 6 (as read from the nameplate; one character partly obscured – Not verified) |
| Date of Manufacture | Not clearly visible in the supplied photograph |
| Power Rating | Not clearly visible in the supplied photograph |
| Country of Manufacture | Japan |
| Condition | Refurbished |
| Supplier | SM MARINE SERVICE™, Chattogram, Bangladesh |
The Fellow Kogyo FOCAS-1800 15ppm Bilge Alarm is a Japanese oil content monitor used with oily water separators on merchant ships. It continuously checks the oil concentration in treated bilge water and gives an alarm when the oil content goes above 15 ppm, so overboard discharge can be stopped. SM MARINE SERVICE™ supplies refurbished FOCAS-1800 units and related spare parts to ship owners, ship managers and repair companies worldwide. Visit https://www.smmarineservice.com/ for more marine automation and navigation equipment.
The FOCAS-1800 is a 15ppm bilge alarm, also called an oil concentration detector or OCM. It consists of a control box with display, alarm indicators and terminals, and an attached optical detector unit through which the sample water flows. The unit is installed on the discharge line of the oily water separator (OWS) and signals the three-way valve or discharge valve to stop overboard discharge when the 15 ppm limit is exceeded, in line with MARPOL Annex I.

Fellow Kogyo FOCAS-1800 15ppm Bilge Alarm with optical detector unit – refurbished, SM MARINE SERVICE™
| Measuring Method | Full optical continuous measurement |
| Measuring Range | 0 – 30 ppm (manufacturer brochure) |
| Alarm Set Point | 15 ppm factory setting (optional 5/15 ppm selection) |
| Operation | Automatic by sample water pressure, or test operation by switch |
| Sample Water Pressure | Approx. 0.03 – 0.3 MPa (manufacturer brochure) |
| Sample Flow Rate | Approx. 0.2 – 3 L/min (manufacturer brochure) |
| Sample Water Temperature | Approx. 2 – 45 °C (manufacturer brochure) |
| Recorder Output | 4 – 20 mA DC |
| Alarm Outputs | Oil concentration alarm contacts, trouble (defect) alarm, power failure alarm, solenoid valve control contact |
| Power Supply | AC 90 – 240 V, 50/60 Hz (manufacturer brochure; check the nameplate of your unit) |
| Pipe Connections | Sample inlet, fresh water inlet and drain: copper pipe OD 8 mm / ID 6 mm |
| Internal Fuse | 3 A ceramic tube fuse, 5 × 20 mm (per instruction manual) |
| Data Recording | Memory card for alarm/operation records, clock with backup battery |
| Variants | Without washing unit (standard) and with washing unit (option) |
| Regulation | IMO MEPC.107(49) |
Specifications are taken from the manufacturer's brochure and instruction manual and may vary by version. Always check the nameplate of your unit.
The FOCAS-1800 contains the following main electronic assemblies. Public manufacturer documents do not list the individual PCB part numbers, so they are marked Not verified. If one board in your unit has failed, send us a photo of the board label and we will search for it.
Calculates the oil concentration from the optical sensor signals, drives the ppm display, manages alarm logic, the memory card and the clock. Part number: Not verified.
Converts the ship's AC supply to the internal DC voltages and carries the fuse circuit. Part number: Not verified.
Front panel 3-digit ppm display and LEDs (Oil Alarm, Meas. Alarm, Run & BZ Disabled, Memory Status). Part number: Not verified.
Oil alarm, trouble alarm, power failure alarm, solenoid valve and 4–20 mA recorder output terminals. Part number: Not verified.
Stainless detector block with the sample detection tube and optical elements (light source and receivers) mounted on the left side of the control box. Part number: Not verified.
Stores alarm and operation records required for oily water discharge records. Listed as replaceable items in the instruction manual.

FOCAS-1800 nameplate: USCG 162.050/9039/0, EC MED-B-3039, Korea BAM-5, China DB05T00016, Canada CBA-015, type approval M-248
Safety note: isolate the power supply before opening the control box, and close the sample and fresh water valves before opening the detector unit. Work should be done by qualified marine engineers or technicians following the manufacturer's instruction manual.
The documented alarm types are: Oil (concentration) alarm, Trouble (defect) alarm, Water cut-off alarm, Power failure alarm and CAUTION indication for detection tube stain. The unit also shows self-diagnostic error codes; refer to the official instruction manual for code meanings.
SM MARINE SERVICE™ can supply refurbished Fellow Kogyo FOCAS-1800 bilge alarms and source related parts on request. For a fast quotation, please send:
We ship worldwide by courier and air freight to ports in Asia, the Middle East, Europe, Africa and the Americas.
Many ships built in the 2000s were delivered with the FOCAS-1800 as part of their oily water separator system. Replacing a type-approved bilge alarm with a different make can mean extra installation work and approval paperwork, so many owners prefer an identical refurbished FOCAS-1800 or replacement parts to keep the existing system running and survey-ready.
It is a 15ppm bilge alarm (oil content monitor) made by Fellow Kogyo Co., Ltd., Japan. It continuously measures oil concentration in the oily water separator discharge and gives an alarm above 15 ppm.
The manufacturer states it complies with IMO MEPC.107(49). The unit shown carries USCG 162.050/9039/0, EC MED-B-3039, Korea BAM-5, China DB05T00016 and Canada CBA-015 approval markings.
Public sources do not list the internal PCB part numbers. Send us a clear photo of the board label and we will check our stock and sources.
We can source boards and parts on request. Please send the board number, photos and the unit serial number for a quotation.
FOCAS-2000 is the later Fellow Kogyo 15ppm bilge alarm model. Compatibility of parts must be checked by model and board number.
FOCAS-1500C is an earlier Fellow Kogyo bilge alarm model. Parts are not automatically interchangeable.
A common reason is a dirty sample detection tube or low/no sample flow. Clean the detection tube as described in the manual and check the sample and fresh water lines.
IMO MEPC.107(49) requires an accuracy check at the IOPP renewal survey; follow the manufacturer's and class requirements for calibration.
Model, serial number, nameplate photo, PCB or part number, vessel name and delivery port.
Yes. SM MARINE SERVICE™ ships worldwide from Bangladesh and China.
The Fellow Kogyo FOCAS-1800 is a Japanese 15ppm bilge alarm (oil content monitor) used with oily water separators on ships. It continuously measures oil concentration by an optical method and alarms when the discharge exceeds 15 ppm, as required under MARPOL Annex I and IMO MEPC.107(49). The unit shown carries USCG 162.050/9039/0, EC MED-B-3039, Korea BAM-5, China DB05T00016 and Canada CBA-015 approval markings. It provides a ppm display, oil and trouble alarms, 4–20 mA output and memory card recording. SM MARINE SERVICE™ supplies refurbished FOCAS-1800 units and sources related spare parts for vessels worldwide.
Available Equipment Conditions: New • Used • Refurbished • Reconditioned (Specific product condition and availability are subject to confirmation.)
Stock Locations: Bangladesh • China
Services: Worldwide Shipping • Technical Support • Spare Parts Supply • Marine Equipment Sourcing
Samir Market, DT Road, Pahartali, beside CDA Market, Chattogram, Bangladesh
Mobile / WhatsApp / Viber: +88 01818 929292
Email: info@smmarineservice.com
Website: https://www.smmarineservice.com/
Send us your model, serial number and photos today for a quick quotation on the Fellow Kogyo FOCAS-1800 bilge alarm or its spare parts.
0
Marine Equipment Supplier