Thorn System T280 Marine Fire Alarm Control Panel 32 Zone

Item Code:

T280

Brand:

Thorn Security (AFA-Minerva)

Condition:

Refurbished


Thorn System T280 Marine Fire Alarm Control Panel – 32 Zone (AFA-Minerva)

Product Information

Manufacturer Thorn Security (AFA-Minerva; later Tyco / Johnson Controls)
Model System T280 (T-280)
Product Type Conventional fire alarm control / indicating panel, 32 zones
Zones on front panel Zone 1 to Zone 32
Part Number Not clearly visible in the supplied photograph (T280 panels are listed by suppliers as AFA-Minerva 523, part no. 1/03047)
Serial Number Not clearly visible in the supplied photograph
Country of Manufacture Not clearly visible in the supplied photograph
Condition Refurbished
Supplier SM MARINE SERVICE™, Chattogram, Bangladesh

Product Introduction

The Thorn System T280 is a conventional marine fire alarm control panel by Thorn Security (AFA-Minerva), installed on the bridge or in the fire control station of many cargo ships, tankers and offshore vessels. This unit shows 32 fire detection zones with individual zone lamps and system status indicators. SM MARINE SERVICE™ (https://www.smmarineservice.com/) supplies Thorn T280 panels and spare parts in refurbished condition to ship owners, ship managers and fire safety service companies worldwide.

What Is This Equipment?

The T280 receives signals from conventional smoke, heat and flame detectors and manual call points arranged in zones around the ship (for example navigation bridge deck, accommodation decks, engine room decks, emergency generator room, steering gear room and stores). When a detector or call point operates, the panel lights the zone lamp, shows "Fire Alarm" and drives the alarm sounders. The panel also supervises its own wiring and power supplies and signals faults such as zone indicator fault, mains fault, standby supply fault and sounder wiring fault. A key switch on the front panel controls access to operator functions, and a zone table on the panel front lists each zone and circuit number.

Main Features

  • 32 conventional detection zones with individual zone indicators
  • Fire Alarm and Fire Alert indicators
  • Fault indicators: Fault, Zone Indicator Fault, Mains Fault, Standby Supply Fault, Sounder Wiring Fault
  • Zone Test and Zone Isolated indicators for maintenance
  • Spare Lamps indicator
  • Key switch for operator access control
  • Mains supply with standby (battery) supply supervision
  • Fire alarm zone table on the front panel
  • Wall-mounted housing with hinged front for ship installation

Thorn System T280 marine fire alarm control panel 32 zone refurbished - SM MARINE SERVICE
Thorn System T280 32-zone marine fire alarm control panel – supplied by SM MARINE SERVICE™

Main Technical Specifications

Model Thorn System T280
System type Conventional fire detection and alarm
Zones 32 (as shown on the front panel)
Status indicators Fire Alarm, Fire Alert, Spare Lamps, Zone Test, Fault, Zone Indicator Fault, Mains Fault, Standby Supply Fault, Sounder Wiring Fault, Zone Isolated
Operator access Key switch
Power supply Mains with standby battery supply (voltage: Not clearly visible in the supplied photograph)
Detectors Conventional smoke, heat, flame detectors and manual call points (types: Not verified)
Supplier part number reference AFA-Minerva 523, 1/03047 (supplier listings; not shown in photo)
Dimensions / weight Not clearly visible in the supplied photograph

Inside the Unit: PCBs, Modules & Part Numbers

Thorn does not publish a public parts list for the T280. The numbers below were found in spare parts supplier listings; boards without a confirmed number are listed by function and marked "Not verified". Please send photos of the board labels for an exact match.

1/03047 – T280 Panel (AFA-Minerva 523)

Part number given by suppliers for the Thorn System T280 fire alarm panel.

1/03398 – Repeater Assembly

Listed by a supplier as "Repeater Assy." for the T280 system (exact compatibility: Not verified).

1/03048, 1/03057, 1/03059

Numbers that appear with T280 panel listings; their function is Not verified.

Main Control / Processor Board

Evaluates zone signals and controls indicators and outputs. Part number: Not verified.

Zone / Detection Circuit Boards

Monitor the 32 detector zones for alarm, open circuit and short circuit. Part number: Not verified.

Display / Indicator Board

Drives the zone lamps and status indicators on the front panel. Part number: Not verified.

Power Supply and Battery Charger Board

Supplies the panel from mains and charges / supervises the standby batteries. Part number: Not verified.

Sounder / Relay Output Board

Drives alarm sounders and outputs to other ship systems, with sounder wiring supervision. Part number: Not verified.

Main Components & Related Units

  • Thorn T280 fire alarm control panel (this unit)
  • T280 repeater panel / repeater assembly 1/03398
  • Conventional smoke detectors, heat detectors and manual call points
  • Alarm sounders and beacons
  • Standby batteries
  • Related Thorn / Minerva / Tyco marine panels: Thorn T880, Tyco T1200 / T1216 series

Marine & Industrial Applications

  • Fire detection on cargo ships, bulk carriers, tankers and container ships
  • Accommodation, navigation bridge and engine room zones
  • Emergency generator room, steering gear room and stores
  • Offshore units and port installations

Thorn T280 fire alarm panel indicators Fire Alarm Fire Alert Mains Fault Standby Supply Fault Sounder Wiring Fault
Thorn T280 status indicators: Fire Alarm, Fire Alert, Fault, Mains Fault, Standby Supply Fault, Sounder Wiring Fault

Common Problems & Troubleshooting

  • Mains Fault: check the mains supply, fuses and power supply board.
  • Standby Supply Fault: check the batteries, battery fuse and charger.
  • Zone fault / Zone Indicator Fault: check the zone wiring, end-of-line device and zone lamp.
  • Sounder Wiring Fault: check sounder cables and end-of-line devices.
  • Repeated false alarms in one zone: check and clean detectors in that zone.
  • Lamps not lighting: use the lamp test and replace failed lamps.

Safety note: the fire alarm system is safety-critical. Inform the bridge and arrange alternative fire watch before isolating zones or working on the panel, isolate the power before opening it, and let only qualified technicians repair the system.

Common Alarms

The front panel of this unit shows the following indications: Fire Alarm, Fire Alert, Fault, Zone Indicator Fault, Mains Fault, Standby Supply Fault, Sounder Wiring Fault, Zone Test, Zone Isolated and Spare Lamps.

Maintenance Tips

  • Test each zone with detector test equipment as required by the ship's safety plan
  • Test standby batteries and replace them at the recommended interval
  • Check indicator lamps regularly and keep spare lamps
  • Keep the zone table up to date
  • Keep the panel clean, dry and closed

Spare Parts & Replacement Availability

SM MARINE SERVICE™ supplies the Thorn System T280 panel, repeater and PCBs. For a quotation, please send the vessel name, photos of the panel front and rating label, photos of any PCB label (part number), the number of zones, and the quantity. We ship worldwide.

Why This Equipment Is Still Used

Thorn T280 panels are still in service on many older ships. Replacing a faulty panel or board with the same model keeps the existing detector wiring, zone layout and approvals unchanged and avoids a complete new fire detection installation.

FAQ

What is the Thorn System T280?
A conventional marine fire alarm control panel by Thorn Security (AFA-Minerva).

How many zones does this panel have?
This unit shows 32 zones.

What is the part number of the T280?
Suppliers list the T280 panel as AFA-Minerva 523, part no. 1/03047.

Is there a repeater panel for the T280?
Yes, a repeater assembly listed as 1/03398 (compatibility: Not verified).

Which PCBs are inside the T280?
Main control board, zone boards, display / indicator board, power supply / charger and sounder / relay output board. Board part numbers are not verified.

Can you supply a single PCB for the T280?
Please send the board label photo and we will check availability.

What does "Standby Supply Fault" mean?
It indicates a problem with the standby (battery) supply.

Who makes the T280 now?
Thorn Security later became part of Tyco, now Johnson Controls.

Is this panel refurbished?
Yes, it is offered in refurbished condition.

Do you ship worldwide?
Yes, SM MARINE SERVICE™ ships worldwide.

Short Product Description

The Thorn System T280 is a conventional marine fire alarm control panel from Thorn Security (AFA-Minerva), used on cargo ships, tankers and offshore vessels. This unit has 32 detection zones with individual zone lamps, Fire Alarm and Fire Alert indicators, and fault indicators for mains, standby supply, zone indicators and sounder wiring, plus Zone Test and Zone Isolated functions and a key switch. Suppliers list the panel as AFA-Minerva 523, part no. 1/03047, with repeater assembly 1/03398. SM MARINE SERVICE™ supplies the Thorn T280 panel and its spare parts in refurbished condition, with worldwide shipping.


SM MARINE SERVICE™ – Marine Automation & Navigation Equipment Supplier

Available Equipment Conditions: New • Used • Refurbished • Reconditioned (Specific product condition and availability are subject to confirmation.)

Stock Locations: Bangladesh • China

Services: Worldwide Shipping • Technical Support • Spare Parts Supply • Marine Equipment Sourcing

Samir Market, DT Road, Pahartali, beside CDA Market, Chattogram, Bangladesh

Mobile / WhatsApp / Viber: +88 01818 929292

Email: info@smmarineservice.com

Website: https://www.smmarineservice.com/

Contact SM MARINE SERVICE™ today for a quotation on the Thorn System T280 Fire Alarm Panel.


BDT:

0

-
+

Related products

Seres ODME MK III Oil Discharge Monitoring Equipment Control Unit

BDT 0

Seres ODME MK III Oil Discharge Monitoring Equipment Control Unit

BDT 0

Seres ODME MK III Oil Discharge Monitoring Equipment Control Unit

BDT 0

KONGSBERG GT404D4H25T Pressure Transmitter | GT404 25 Bar Marine Cargo Line & Manifold Pressure Sensor

BDT 0

SM Marine Service

SM Marine Service

Marine Equipment Supplier

Welcome to SM Marine Service! How can we help you today? 7:56 PM
Need Help? Chat with us