Tyco Flame Detector | Marine UV/IR Flame Detector | Fire Detection Sensor for Ship Fire Alarm Systems | SM MARINE SERVICE™

Item Code:

Flame detector

Brand:

Tyco Fire Protection Products

Condition:

New product


Manufacturer

Tyco Fire Protection Products

Country of Origin

United Kingdom / United States (Depending on Model & Production Facility)

Product Type

Marine UV/IR Flame Detector

Marine Application

Marine Fire Detection & Fixed Fire Alarm System


Tyco Flame Detector for Marine Fire Protection Systems

https://images.openai.com/static-rsc-4/7ob7mBXQqXojNsL1abvkXYuRUDUtfUfVGqFXnoNRz7gin-TNorQhulcMiK7ME_ecYbB6wjr1aWd4MA_r4LnL1mJFZp9KtSUSz2aFAay2lKxmkJ3V4sLenTdEzsoZf0H8MheWoNUa3uVjIqyGKawlgxROPmP6APYebCnyxqYz6_yjWTofb8Mr4jy0siLrNhzB?purpose=fullsize
https://images.openai.com/static-rsc-4/ky1D56DbmE82IFTPr-krR86jxFrdm6_BJsnRzRd5t1pAdJHALOdSkvOqoW80Ppd_CkQFP-TANk9guzkY6cSYfp3_EoXkZTwztLAKFmi8oelrKkpNsaUKNA8fCxrnP-7U7W-c3IwTrt_x_xbwuSl7qxv14EbzztcIYs3NDj5iowiM8j_Ux58SY-n7O8Bi_Iml?purpose=fullsize
https://images.openai.com/static-rsc-4/yCeoknLD4istvKqpO7PnXvPpQiv5zQs25vxNIIojwYPDS0pGq3SANlQQiSInDG2DSPMm48GejXKWOgY5DfHStS_9A2obtLnHialxTN67K0lIC0Liltru8CI48-ch_zvzwRV1LWBAhu8Q7OUol5p8zKP5Khk8rR43ovotF5o1QyI2IxA1lw-7ZQogX78XHFwY?purpose=fullsize

Product Introduction

The Tyco Flame Detector is a marine-approved fire detection device designed to detect ultraviolet (UV) and infrared (IR) radiation emitted by open flames. Unlike conventional smoke or heat detectors, flame detectors provide almost instantaneous fire detection, making them ideal for high-risk shipboard areas where combustible liquids and gases are present.

Tyco flame detectors are widely installed on merchant vessels, offshore platforms, FPSOs, LNG/LPG carriers, tankers, and naval vessels, providing reliable protection against fuel fires, oil fires, and gas ignition hazards.

These detectors integrate with Tyco Fire Alarm Control Panels and other marine fire detection systems, helping crews respond quickly to fire incidents and minimize damage.


https://images.openai.com/static-rsc-4/s70vK2XfUFbND0945jjzOd2fhE3lw4AS_hnXPbTv1MNRL9nDy1Id0nAQGwdy2TF9QM5Ok1XDnOwzx17GOM8Oy8yrgzHdSLW8f2RVU-A-7uF4tBKSpWTLFcSScAQt3VILzV7WjrFG10nzlHOzHUZ0lRrYYOVeF3ve8QmReOLC0zs2Ja9TPHpmshoRkThWEEmE?purpose=fullsize
https://images.openai.com/static-rsc-4/S5BvwNpg7Bzxuge3UmK-2dAnZ9XkU6HnOXLdYC_GEUNzuzarz7KmhkcAyGG_4c97xBiVFgJPkzquNQNAxEnfW40kAGHcfxQBTdn3J8Tl4htnL87XQ4SBUP2Ha3VzyYuTTofROjpgu3ohrPnIijRbBfavU2VXf8rA5OQ5OUb93PwzZ8cwDRngP-U8xJZUw_Hy?purpose=fullsize
https://images.openai.com/static-rsc-4/aSebyP0jJ_erjaBeuT9tCdT5kn7Jd5oBFKuR96PhivEB-2dcW4MTnVBfyfukhiFsWL9m5j1im1jCQi8BdGjfPQJ6Gk2l5ySHzOVg3z5Z89CSo1IUruKZc7xDM6irH4GN2r038NNcDn1X-ThyO4jzAANwFMa-e8bUJA8Y1Y_bpcdyOBkG6fOQG2H0QMEbYQIe?purpose=fullsize

What Is This Equipment?

A Tyco Flame Detector continuously monitors its field of view for the unique UV and IR radiation produced by flames.

When a flame is detected, the detector immediately sends an alarm signal to the ship's Fire Alarm Control Panel (FACP), allowing automatic shutdowns, fire suppression activation, and rapid crew response.

Compared with smoke detectors, flame detectors react much faster to rapidly developing fires involving:

  • Fuel Oil
  • Diesel Oil
  • Hydraulic Oil
  • Lubricating Oil
  • Gas Leaks
  • Flammable Liquids

Main Features

  • UV/IR flame detection technology
  • Rapid fire detection response
  • Marine-approved design
  • High immunity to false alarms
  • Long detection range
  • LED alarm indication
  • Rugged corrosion-resistant housing
  • Continuous self-monitoring
  • Low maintenance requirements
  • Reliable operation in harsh marine environments
  • Compatible with marine fire alarm systems

https://images.openai.com/static-rsc-4/ky1D56DbmE82IFTPr-krR86jxFrdm6_BJsnRzRd5t1pAdJHALOdSkvOqoW80Ppd_CkQFP-TANk9guzkY6cSYfp3_EoXkZTwztLAKFmi8oelrKkpNsaUKNA8fCxrnP-7U7W-c3IwTrt_x_xbwuSl7qxv14EbzztcIYs3NDj5iowiM8j_Ux58SY-n7O8Bi_Iml?purpose=fullsize
https://images.openai.com/static-rsc-4/7ob7mBXQqXojNsL1abvkXYuRUDUtfUfVGqFXnoNRz7gin-TNorQhulcMiK7ME_ecYbB6wjr1aWd4MA_r4LnL1mJFZp9KtSUSz2aFAay2lKxmkJ3V4sLenTdEzsoZf0H8MheWoNUa3uVjIqyGKawlgxROPmP6APYebCnyxqYz6_yjWTofb8Mr4jy0siLrNhzB?purpose=fullsize
https://images.openai.com/static-rsc-4/L6bnh_nnoxBfAIaCmp0w4xai_mkooZXX2EwIAqC7rheHQWHTCEaS-movvpzKiKSbVHXJqZ2cKojpZwa9Mbi4cVwSZzwnBEumb7oTYjdyH6L26JZrsy_05BY90OtCBq-gN1TRmn6nKPTPAMSCe3URa5vPkt8K561eAziE_UvJS6AlqDIfCtndZYyc2K_eaKf4?purpose=fullsize

Main Components

A typical Tyco Flame Detector includes:

  • UV Sensor
  • IR Sensor
  • Optical Window
  • Signal Processing Circuit
  • Microprocessor
  • LED Status Indicator
  • Protective Housing
  • Mounting Base
  • Electrical Terminal Block
  • Self-Diagnostic Circuit

Marine Applications

Tyco Flame Detectors are commonly installed in:

  • Engine Rooms
  • Boiler Rooms
  • Fuel Oil Purifier Rooms
  • Cargo Pump Rooms
  • LNG Pump Rooms
  • Hydraulic Power Units
  • Incinerator Rooms
  • Generator Rooms
  • Offshore Platforms
  • FPSOs
  • Chemical Tankers
  • Oil Tankers
  • LNG/LPG Carriers
  • Machinery Spaces
  • Hazardous Process Areas

https://images.openai.com/static-rsc-4/JxtcIG8c6-XcA3ywjp47yodkbQSDCl2kRml2o1V6BW7wVnvfd_OrNQMWQ4vofBFC3W9s4-8eR1hzTLhuBBhd4M1SC50-9CNDY7JFic-W8dRwpwQaKg_IwpuNj7AhleSm0aEI7Clc_dri_zaUs70jCrFmlk0rbgSob4y9gUSoixhzXPo-STjz2FPXfCqNTJ4v?purpose=fullsize
https://images.openai.com/static-rsc-4/s70vK2XfUFbND0945jjzOd2fhE3lw4AS_hnXPbTv1MNRL9nDy1Id0nAQGwdy2TF9QM5Ok1XDnOwzx17GOM8Oy8yrgzHdSLW8f2RVU-A-7uF4tBKSpWTLFcSScAQt3VILzV7WjrFG10nzlHOzHUZ0lRrYYOVeF3ve8QmReOLC0zs2Ja9TPHpmshoRkThWEEmE?purpose=fullsize
https://images.openai.com/static-rsc-4/auZGB4wogbZvzrSAAwjrTCUP4gBm_0l9cSRW2VJXtSn6U2h8lQsvwFBhQvqfmND5TPXD4-dcyMSrsoxqTrTa3Bgq_0FSKK24Nli62GUdZykhXXKQugT_lrsEpgGnhwCnnVsXWQI1GJEf8K3z0k5-xM7tAC_HLlD5p74WQjoI6XDFS1K5KWkO7QEUsuMuk7X3?purpose=fullsize
5

Common Problems & Troubleshooting

Problem Possible Cause Recommended Solution
False flame alarm Dirty optical window or strong UV source Clean the optical window and inspect the installation area
Detector fault Internal electronics failure Replace or repair the detector
No alarm during flame test Sensor contamination or wiring fault Inspect optics, wiring, and perform a functional test
Communication fault Loose cable or control loop issue Check cable continuity and terminal connections
LED not illuminated Power supply failure Verify supply voltage and fire alarm loop
Frequent fault indication Moisture or damaged optics Inspect seals and replace damaged components

Maintenance Tips

To ensure dependable performance:

  • Clean the detector lens regularly using approved materials.
  • Inspect for dust, oil mist, and salt deposits.
  • Test detector response during routine fire system maintenance.
  • Check mounting alignment toward the protected hazard area.
  • Verify cable glands remain watertight.
  • Inspect terminal connections for corrosion.
  • Record all inspections in the vessel's Planned Maintenance System (PMS).

Why Ships Still Use Tyco Flame Detectors

Tyco flame detectors continue to be trusted throughout the marine industry because they offer:

  • Extremely fast flame detection
  • High sensitivity to hydrocarbon fires
  • Low false alarm rates
  • Reliable operation in harsh environments
  • Excellent compatibility with marine fire alarm systems
  • Proven long-term performance
  • Worldwide technical support and spare parts availability

These advantages help protect vessels, crew, cargo, and machinery from serious fire incidents.


Frequently Asked Questions (FAQ)

What does a Tyco Flame Detector detect?

It detects the ultraviolet and/or infrared radiation emitted by open flames, allowing rapid fire detection.

Where are Tyco Flame Detectors installed?

They are commonly installed in engine rooms, boiler rooms, cargo pump rooms, fuel handling areas, offshore platforms, and other hazardous locations.

Can a flame detector replace a smoke detector?

No. Flame detectors complement smoke and heat detectors by providing faster detection of open flames. A complete marine fire protection system typically uses all three technologies.

How often should the detector be tested?

Testing should be carried out during scheduled maintenance in accordance with the manufacturer's recommendations, classification society requirements, and the vessel's Planned Maintenance System.


Short Product Description

The Tyco Flame Detector is a marine-grade UV/IR flame detection sensor designed for rapid identification of hydrocarbon fires in hazardous shipboard environments. Widely used in engine rooms, pump rooms, and offshore facilities, it delivers reliable flame detection, fast alarm activation, and dependable fire protection for commercial and offshore vessels.

SM MARINE SERVICE™

Marine Automation & Navigation Equipment Supplier

Available Condition

  • New Equipment
  • Used Equipment
  • Refurbished Equipment
  • Reconditioned Equipment

Stock Location

  • Bangladesh
  • China

Services

  • Worldwide Shipping
  • Technical Support
  • Spare Parts Supply
  • Marine Equipment Sourcing

Contact Information

SM MARINE SERVICE™
Samir Market, DT Road, Pahartali, beside CDA Market, Chattogram, Bangladesh

Mobile / WhatsApp / Viber: +88 01818 929292

Email: info@smmarineservice.com

Website: www.smmarineservice.com


BDT:

0

-
+

Related products

Deckma OMD-21 Oil Content Meter | 15 PPM Bilge Alarm

BDT 0

BRANNSTROM CLEANTRACK 1000B Oil Discharge Monitoring and Control System (ODME)

BDT 0

Saginomiya SNS-C106X60 Pressure Control Switch – Marine Refrigeration, HVAC & Compressor Protection Control

BDT 0

BD-Sensors

BDT 0

SM Marine Service

SM Marine Service

Marine Equipment Supplier

Welcome to SM Marine Service! How can we help you today? 10:18 PM
Need Help? Chat with us