WhatsApp : +88 01818929292 / +8801730296909
info@smmarineservice.com sohelbhuiyan1213@gmail.com arafatbhuiyan3657@gmail.com
WhatsApp : +88 01818929292 / +8801730296909
info@smmarineservice.com sohelbhuiyan1213@gmail.com arafatbhuiyan3657@gmail.com
Product Image
Product Image

Graviner MK5 Oil Mist Detection

Item Code:

Graviner MK5 Oil Mist Detection

Brand:

GRAVINER

Condition:

Refurbished


 Title

Graviner MK5 Oil Mist Detector (OMD) | Marine Main Engine Oil Mist Detection System | Fire & Explosion Protection | SM MARINE SERVICE™


 Description

Graviner MK5 Oil Mist Detector (OMD)

Intelligent Main Engine Oil Mist Detection System for Marine Engine Protection

https://images.openai.com/static-rsc-4/07Ty2fH3P2K4t1EBI56GmLM-Ovo3C0Un5_wajmMkQ7gjsV7YqmO_-gS68qYPORpwtIjELjUX-F5-d3HDywVqjqWKIHF-qMDL-wdaKpgNx4LMwSLgDW1JJBL0LNtXZBONX6J4-uKnV-undldU4u46ZKVdW5WOE9w8bgkIoQ6S29X5r2SDcxB-qhaR1Ymxrd1I?purpose=fullsize
https://images.openai.com/static-rsc-4/xGgsZM-Kam3TjqLiramSvAanR6XgD558kLLIcL9iDJ_r0lM4N20xc_9rUF67x0bfhlaea-Fddx-OgVP1tpqtBHg4v4OJqovUVImeU58MSqyjhkiTM4gemK2duFDI0yN7gJDEPxAjy0x3lrvMpuCtHhnYSt0fLj8KI4pxs9sMwp-bLjgmKkWnpvUxq0TrdEjw?purpose=fullsize
https://images.openai.com/static-rsc-4/PfeA_mrFY6PCku4FtTOR13TwiOVsVIWHUZNCXyiEuVrbEhEocv_-iM1lp6prmGjTelj65skA-kLkEtFg6OA7V4JWg8uTSM9M4CwyFv-LOBjTeT2kszgRi1KaxF0Fl5wsVw4VFGecRjI7ZkEuCcemoHovzxm8o8E2TfUfFrPYrBBWbREbWui_l2ooC8S4NC9G?purpose=fullsize
4

The Graviner MK5 Oil Mist Detector (OMD) is one of the most widely installed marine engine safety systems used on two-stroke and four-stroke diesel engines. Designed to continuously monitor crankcase oil mist concentration, the MK5 provides early warning of abnormal conditions that could lead to crankcase explosions, severe engine damage, or vessel downtime.

By continuously sampling air from each crankcase compartment, the MK5 detects rising oil mist levels before dangerous conditions develop. If the oil mist concentration exceeds preset alarm limits, the system immediately activates audible and visual alarms, enabling engineers to take corrective action before a catastrophic engine failure occurs.

The Graviner MK5 has earned a strong reputation across the maritime industry for its reliability, accuracy, and compliance with SOLAS and classification society requirements. It is widely installed on MAN B&W, Wärtsilä, Sulzer, Mitsubishi, Daihatsu, Yanmar, Himsen, MAK, and other major marine diesel engines.

SM MARINE SERVICE™ supplies new, used, and professionally reconditioned Graviner MK5 Oil Mist Detectors, including control units, detector heads, sampling manifolds, display modules, PCB boards, spare parts, repair services, calibration, and worldwide technical support.


Manufacturer Information

Item Details
Manufacturer Kidde Graviner Ltd.
Product MK5 Oil Mist Detector
Product Type Oil Mist Detection System (OMD)
Marine Application Main Engine Crankcase Protection
Compliance SOLAS / IACS / Marine Classification Rules

https://images.openai.com/static-rsc-4/u2r5GnFU6vWMEgSFHI4SmK4Mbi57BiICtBQKPDbFVoNPqtvVP5bOKO9xB9HTZmrEX2vjM3tPdZVQEMxw1C8NcWYRm-FF_9U2rODLo95kyxjP0r71AUzB6BJS1z4PG9lh-jlcFHl3P-sWbcv5xtw1ar6OEXZIgyZVQyqwfelKZlmestrTKJDncWUzHjYgCY8f?purpose=fullsize
https://images.openai.com/static-rsc-4/FCNPocvub0h_EkkECoI5gNb1Wu0S7Lc1-TA-XZD9ZzbISDi828HRecXzCmhr7Afx7JoABywi6KIZ7Y0LAQ-f08sGkBBQR-zyLTUpBXsgqaj9fljUXDbMKyMdeD5IQZBQfZCM226tinp2UYzlqH12vd3opzBu-gNSQ2XkF99I5boNO7tjLTnVePS8Q3QXiPQ7?purpose=fullsize
https://images.openai.com/static-rsc-4/D1sBD2bBn51fdeTJTte5-MCMwZ1PmQDljjjZumJFjIWGoYcJQr854-IvlZGH-8JgjTFYvDuhPeLMbS-ivbkrhsqGsTeVOkYQ8Vrn6BKlBLTlFXexr9I0Cqs4pNVo5K82h2hlOzfQnEB89ypJP7NcL_5JWbCCnTHkKz4JA6J5_3XWkiI_N9c9x_zurrFOxA5x?purpose=fullsize

What Is the Graviner MK5 Oil Mist Detector?

The Graviner MK5 is an intelligent monitoring system designed to detect microscopic oil particles suspended inside a diesel engine crankcase.

During normal engine operation, oil mist levels remain very low. However, bearing failures, overheating, friction, or lubrication problems can rapidly increase oil mist concentration. If left undetected, this can ignite and result in a crankcase explosion, causing severe engine damage and serious safety risks.

The MK5 continuously samples air from each crankcase compartment, measures oil mist density using optical sensing technology, and compares the readings against preset alarm thresholds. When abnormal levels are detected, the system generates alarms and can interface with engine protection systems.


https://images.openai.com/static-rsc-4/w_Utlz70TTdPmeTIWDzzryr35MgWlGSskxYYDvqsZf-o0qs7DKoiV3i_JXjikS8M5g9sLRFyYp0H2KN5hBiB0ukWSR2t7_zbfT-vNvKs_LfSn9IXbUwhPhNhCQQgbe2MdwJ_Fnk9_icrWRHf6ha71YfFWXFRk2oTXUfcINo5b0qUFcScTwlk9kI7kTyyTqM3?purpose=fullsize
https://images.openai.com/static-rsc-4/07Ty2fH3P2K4t1EBI56GmLM-Ovo3C0Un5_wajmMkQ7gjsV7YqmO_-gS68qYPORpwtIjELjUX-F5-d3HDywVqjqWKIHF-qMDL-wdaKpgNx4LMwSLgDW1JJBL0LNtXZBONX6J4-uKnV-undldU4u46ZKVdW5WOE9w8bgkIoQ6S29X5r2SDcxB-qhaR1Ymxrd1I?purpose=fullsize
https://images.openai.com/static-rsc-4/vhTS5vD3EprkmztTF_6jFAK2rvfdomtRRfqoz2SCqwQY4Qr-MEEpfQHXFosvVua0pcmFjk1f1XXL_Kz-jASf5M73Qhh89cJ7tYddt5tirW_Z81oD9Bbf-tjxgtFvNblPvl4Pv7zxmakd7UuHinx1-gahiXk6oBNtHwjyZAcWCo4XfuWayiSpu2IqWYgbdxL4?purpose=fullsize
5

Key Features

The Graviner MK5 offers advanced protection features, including:

  • Continuous crankcase oil mist monitoring
  • Optical oil mist detection technology
  • Fast alarm response
  • Individual crankcase sampling
  • Automatic sequential sampling
  • High reliability and accuracy
  • Self-diagnostic functions
  • LCD display with alarm indication
  • Low maintenance design
  • Compliance with international marine safety standards
  • Easy calibration and servicing
  • Long operational life

Discover the Graviner MK5 Oil Mist Detector (OMD)

Main Components of the Graviner MK5 Oil Mist Detector

https://images.openai.com/static-rsc-4/ZliT85Ctbgibzgxq3HyAKprdSeOlNT6bT5Zv-3jwWu9BqJnwbejHBlaDlw7veQ_y7McxMyBiiwjTy5GNtQ_Xd3SjDTa4avp-Q2mCxxe5JQEp5CfDZVWNsX9RYTSbqJEZkCU0dona7psuSmTZED4wCVjhOpPm3abHlLUBC2CJjnKBAUxCRncfwmlYGydGA2JM?purpose=fullsize
https://images.openai.com/static-rsc-4/Gso_W3x4bH1TbJZ-E_sZpCBfIe59mxxU_prBbR3YXOrCUhipPbIXjsgBzsylQh0I7LRixF2CoQhbgd9ogamzV5ZiIyMYS2pyqqkF0ltODFBZ3uyJknE4p_quUXSHGHnPYdMC-JgOMpBdwXVBSwj3Fc4GCv--zkwJ8yHiaGV7pbNDFVXsHy-n9EAqqRLKtlGZ?purpose=fullsize
https://images.openai.com/static-rsc-4/hXdN0vyj83gwhnj5OKjJISBgvdVSYXaGB-e35r7BL8EXEb5UpYWAlP0B19100u8AOc3TFxKzNb_Q-7--wO41YuQ2aVc-Z8U_s8aFnJV7hiGYxhZ9rvnYRRAyfav3o6xlFH2JsMG6CJaVoa9WA2H0S4rHtsUvVoF0NaI-kvfb8p4oeeoWkdfkL8jyN7GUn45i?purpose=fullsize

The Graviner MK5 Oil Mist Detector is composed of several intelligent electronic and mechanical assemblies that work together to continuously monitor crankcase oil mist levels. Each component plays a vital role in ensuring early detection of hazardous conditions and protecting the main engine from crankcase explosions.


1. Control Unit

The Control Unit is the central processor of the MK5 system.

Functions include:

  • System monitoring
  • Alarm processing
  • Sequential sampling control
  • Sensor data analysis
  • Self-diagnostics
  • Communication with engine safety systems

2. Optical Detector Cell

The optical sensor measures the density of oil mist particles using light scattering technology.

Advantages include:

  • High sensitivity
  • Fast response time
  • Stable measurement
  • Low maintenance
  • High detection accuracy

3. Sampling Manifold

The sampling manifold collects air from each crankcase compartment through dedicated sampling pipes.

Its functions include:

  • Sequential air sampling
  • Equal sampling flow
  • Controlled measurement
  • Continuous monitoring

4. Sampling Valve Assembly

Each crankcase sampling point is equipped with a valve that allows the detector to sample one compartment at a time.

This provides:

  • Individual compartment monitoring
  • Accurate location identification
  • Reliable oil mist detection

5. Air Pump

The internal sampling pump continuously draws crankcase air through the detector.

The pump ensures:

  • Stable airflow
  • Accurate sensor readings
  • Continuous operation
  • Reliable monitoring

6. Display & Alarm Module

The display panel provides engineers with real-time operating information.

It indicates:

  • Oil Mist Level
  • Alarm Status
  • Fault Conditions
  • Sampling Position
  • System Health
  • Diagnostic Messages

7. Power Supply Module

The power supply provides stable operating voltage to all internal electronics.

Protection features include:

  • Over-voltage protection
  • Under-voltage protection
  • Short-circuit protection
  • Stable DC output

8. Relay Output Module

The relay outputs can interface with:

  • Engine Alarm System
  • AMS (Alarm Monitoring System)
  • Engine Shutdown System
  • Bridge Alarm Panel
  • IAS (Integrated Automation System)

Technical Specifications

https://images.openai.com/static-rsc-4/Yb9eabpydeh7fwH183f3jy0rUbN4rV5t8-xtSkh3YJ5VpVolZ9z5Qu1TKSRAg_7DWjy1aILPqeKF1zj9tHB8e_UETCeya76r4dl-rXa2WlbmNWqTw9Z3WilCAttwpV5S0K2hbkcZwd5_oX2PZLARTxwP8lyolM6xy-OR0MVTra2vixLsFCoZ57r__22SFWZY?purpose=fullsize
https://images.openai.com/static-rsc-4/7iAmVmGmIMbelIKhUsxFfJgdjb8oY9WXm1PV3qIM1VovTfKtD-1e8q65fKPRA_WsmY2O8PtbG_Khd57miUHHwdOYyQlq4DCY83cvf3onR5qX5i-AtLBJ_mHipmjnvWU4IsdgXsX3oNA25_Yaw-VUZF-KidfOHR3eLetJtk8Hu3hPMRmofrKRjrQcXTMVMELh?purpose=fullsize
https://images.openai.com/static-rsc-4/x8p1ZUduAR--4qgJcxZbmumAW0Qi00xBeDUGFo2kegZDsC0tGWCtkn9VkByBnOPCt5mkancsCn_fH6N6YZILNNr9D9yJ1jF7CkNtTPP6Ml3uneQXXyQzjgjWjeIrl213uKPtrvZdVbuygGRIdGF1NXWpP5cI75wJtzD937ftkJBz6-UA6Uruy2Y4bjQupvpr?purpose=fullsize

Specifications may vary depending on system configuration and engine application.

Specification Details
Manufacturer Kidde Graviner Ltd.
Model MK5 Oil Mist Detector
Detection Method Optical Light Scattering
Product Type Oil Mist Detection System
Sampling Method Automatic Sequential Sampling
Installation Main Engine Crankcase
Alarm Output Visual & Audible
Interface AMS / IAS / Engine Protection System
Compliance SOLAS / IACS / Marine Classification Rules

Marine Applications

https://images.openai.com/static-rsc-4/KDsanrV7x2p92Iy2m-31OatTTpU56Pc_0oxvcAWt8M3-vYcG2_JaVOPy_HWG9RAW0tp0GBTGS7LevockP17AWji9ug4MIlER5e8CFn2aI8HCKYZ16wzXZicD6vxGx2Zm7f6Y2Fp9tHmGxmsRcHVFywwmGUh5u8YtP_PNloj6vOkcQt8naDFv8t5c7CVhp_qp?purpose=fullsize
https://images.openai.com/static-rsc-4/u2r5GnFU6vWMEgSFHI4SmK4Mbi57BiICtBQKPDbFVoNPqtvVP5bOKO9xB9HTZmrEX2vjM3tPdZVQEMxw1C8NcWYRm-FF_9U2rODLo95kyxjP0r71AUzB6BJS1z4PG9lh-jlcFHl3P-sWbcv5xtw1ar6OEXZIgyZVQyqwfelKZlmestrTKJDncWUzHjYgCY8f?purpose=fullsize
https://images.openai.com/static-rsc-4/GXRQhkhyvkKQHUKRDFF6DReA_qwA0pEycUTlFzy2ab9GNNCPe9V2H7vB4axPJ6u99usVuaWFbe81pBcFKKbXDIfu_xEBsX9ByvaQH9vE-rI6iB_yjyjAdp6SDOS2kLxakcId_7oKzgMe1lFIa4B3b8-NResoruXG5JJSDQIhKY38lS5vsUodxWCPT5tqrVi9?purpose=fullsize

The Graviner MK5 is widely installed on:

  • MAN B&W Main Engines
  • Wärtsilä Main Engines
  • Sulzer Main Engines
  • Mitsubishi Marine Engines
  • Daihatsu Diesel Engines
  • Yanmar Marine Engines
  • Himsen Marine Engines
  • MAK Marine Engines
  • Bergen Engines
  • Medium-Speed Diesel Engines
  • High-Speed Marine Diesel Engines
  • Offshore Power Plants

Common Problems & Troubleshooting

https://images.openai.com/static-rsc-4/hXdN0vyj83gwhnj5OKjJISBgvdVSYXaGB-e35r7BL8EXEb5UpYWAlP0B19100u8AOc3TFxKzNb_Q-7--wO41YuQ2aVc-Z8U_s8aFnJV7hiGYxhZ9rvnYRRAyfav3o6xlFH2JsMG6CJaVoa9WA2H0S4rHtsUvVoF0NaI-kvfb8p4oeeoWkdfkL8jyN7GUn45i?purpose=fullsize
https://images.openai.com/static-rsc-4/Vh_cMJ9_mntqGRnUnRCUfeTAhlAEudWNhLOY56DDmFVkh21AM4xwdX6WCi1FjVHKR8X0H1rKvC5pVuGMDqF5GxcP4RJoc8Y-0CC_eUkBF4k2EoQFQWhUZtj0jNVo3r77VyV8g6mMLXugZqNsFIxpUT3PltYA0lIqaOgzIKG3dsrPqu66kdHVyxGYkR4L34Fv?purpose=fullsize
https://images.openai.com/static-rsc-4/IamwhzXfLgqQGYvhIdgf237n5UWguNeadB53WS_Rp2FJm1AcgWKSb6EP5zQGiUPEUChRlNIvZ2b3ARvmsJhWnzz-U1SjFhk3eibyO60gwxB2mUO3VeD8NSIPLjl3n9k5w48LDWJQrFefS-T69Cb4y3_q-5iI8lPuzYA_nqHAqFy9y_2raTaZi9zze3sSsdf1?purpose=fullsize
Problem Possible Cause Recommended Solution
Oil mist alarm Bearing overheating or abnormal oil mist Inspect crankcase immediately and identify the source
High oil mist reading Lubrication failure or mechanical wear Check bearings, lubrication system, and engine condition
Sampling fault Blocked sampling pipe Clean or replace sampling tubing
Pump failure Worn sampling pump Repair or replace the pump
Sensor fault Dirty optical chamber Clean optical detector and recalibrate
Communication failure Cable or PCB issue Inspect communication wiring and control PCB
False alarm Moisture, contamination, or dirty optics Clean sensor and verify calibration
No display Power supply problem Check power input and internal PSU

Routine calibration and periodic functional testing are recommended to maintain system accuracy.


Preventive Maintenance

https://images.openai.com/static-rsc-4/_22u7ZEbfINHgEABOZS8flVQi2COCDooDkWKUIUM8dPbl3TKGnpct25K5f-pk2XkgcbnW16P2rSI-8CWhdb65vjsyOGSm4Vc3SPEiySDQnHttQrr2zX5XQBqcnXqx20eU8WpAHUPlLumBKW5FpmRuT_9rAiC6MC2Lq_r30zdM_veQVtrYNuAjHhBIY3I_YNZ?purpose=fullsize
https://images.openai.com/static-rsc-4/sL3K2GLV_s0IJ-AlcsVGcnqh_jNBify46JkCK4Q_QqVZTzdGj8oF9jZVNU_op3xWjKXwrtv3zhC4qpMDxZIajOQEyWQ_TjWS5IkbnoADQ6ZUenhhQPf38H4JJLTT8nAxeL6DJtDrvcna5-EeRtYINJR0VqplEKmxn6DKdWn-GMXrf0IfR-CLW_o1IVFBgx80?purpose=fullsize
https://images.openai.com/static-rsc-4/-606Xu5JeZxBZZww9DR0PNNJqxvkpsX0h62js0f76ZZWoq9E1hldCMF17bvrVDI0WhnHSzwOz8E0Hrm3DO_OZp7NN246YxEZ27JHBktn1x-1YbdU3tS27oxaRH7TURGS_DI_DLUh5oCf8591GkG-qAn3pJmfz2po8pJDnNvNPmDnvtYq_Z5DkB3AC4eJ1K42?purpose=fullsize
5

To ensure long-term reliability, perform the following maintenance:

  • Inspect sampling pipes for blockage.
  • Clean the optical sensing chamber.
  • Test the sampling pump operation.
  • Verify alarm functions.
  • Check display indications.
  • Inspect electrical connectors.
  • Test relay outputs.
  • Replace filters when necessary.
  • Perform periodic calibration.
  • Record maintenance activities in the engine logbook.

Why Ships Continue to Use Graviner MK5

The Graviner MK5 remains one of the industry's preferred Oil Mist Detection systems because of its:

  • Proven reliability
  • Fast alarm response
  • Accurate optical sensing
  • Low maintenance requirements
  • Robust marine construction
  • Long service life
  • Compliance with SOLAS and IACS requirements
  • Worldwide spare parts availability
  • Easy integration with engine automation systems

It has protected thousands of marine diesel engines around the world for decades.


Frequently Asked Questions (FAQ)

Q1. What is the purpose of the Graviner MK5 Oil Mist Detector?

It continuously monitors crankcase oil mist concentration and provides early warning of abnormal conditions that could lead to crankcase explosions.

Q2. Which engines commonly use the Graviner MK5?

The MK5 is widely installed on engines manufactured by:

  • MAN B&W
  • Wärtsilä
  • Sulzer
  • Mitsubishi
  • Daihatsu
  • Himsen
  • MAK
  • Bergen
  • Yanmar
  • Other medium- and low-speed marine diesel engine manufacturers

Q3. Can the Graviner MK5 be repaired?

Yes. Most faults involving control units, optical sensors, sampling pumps, display modules, PCB boards, power supplies, and relay circuits can be repaired by experienced marine electronics engineers.

Q4. Which spare parts are commonly replaced?

Frequently supplied spare parts include:

  • Control Unit
  • Display Module
  • Optical Detector Cell
  • Sampling Head
  • Sampling Valve
  • Air Pump
  • Power Supply Board
  • CPU PCB
  • Display PCB
  • Alarm Relay Board
  • Sampling Tubes
  • Air Filters
  • Cable Assemblies
  • Connectors

Q5. Does SM MARINE SERVICE™ supply Graviner MK5 systems and spare parts?

Yes. We supply new, used, and professionally reconditioned Graviner MK5 Oil Mist Detectors, spare parts, PCB repair, calibration services, overhaul, and worldwide technical support.


Short Product Description

The Graviner MK5 Oil Mist Detector (OMD) is a highly reliable marine engine safety system that continuously monitors crankcase oil mist concentration using advanced optical detection technology. It provides early warning of abnormal engine conditions, helping prevent crankcase explosions and ensuring compliance with international marine safety standards.


User Manual & Technical Resources

For installation, commissioning, calibration, troubleshooting, maintenance, and repair procedures, always refer to the official Graviner MK5 Installation Manual, Service Manual, Operation Manual, Calibration Guide, Wiring Diagram, and Spare Parts Catalogue corresponding to the exact MK5 system configuration.


Conclusion

The Graviner MK5 Oil Mist Detector is one of the most trusted crankcase protection systems in the maritime industry. Its advanced optical sensing technology, intelligent diagnostics, and proven reliability help safeguard marine diesel engines from potentially catastrophic crankcase explosions. Regular maintenance and timely calibration ensure dependable performance throughout the vessel's operational life.

Whether you require a complete Graviner MK5 Oil Mist Detector, control unit, display module, sampling head, optical sensor, PCB repair, calibration, or replacement spare parts, SM MARINE SERVICE™ provides professional marine engine safety solutions with worldwide sourcing, repair, testing, and technical support.


About SM MARINE SERVICE™

SM MARINE SERVICE™ is a trusted global supplier of marine automation, navigation, communication, fire & safety systems, engine room automation, oil mist detectors, VDR/S-VDR, radar, ECDIS, hydraulic systems, and marine electronic spare parts.

Our Services

  • New, Used & Professionally Reconditioned Marine Equipment
  • Graviner MK5 Oil Mist Detection Systems
  • Oil Mist Detector Repair & Calibration
  • PCB-Level Electronic Repair
  • Genuine & Replacement Spare Parts
  • Worldwide Equipment Sourcing
  • Functional Testing & Calibration
  • Technical Support
  • Global Export & Shipping Services

Bangladesh Office

Samir Market, DT Road, Pahartali, Beside CDA Market, Chattogram, Bangladesh

China Warehouse & Support Center

Shanghai, China

Contact

Website: www.smmarineservice.com

Email: info@smmarineservice.com

WhatsApp: +8801818929292

Marketing Contact: Nazmul Hasan Bhuiyan


 


BDT:

0

-
+

Related products

Deckma OMD-21 Oil Content Meter | 15 PPM Bilge Alarm

BDT 0

BRANNSTROM CLEANTRACK 1000B Oil Discharge Monitoring and Control System (ODME)

BDT 0

Saginomiya SNS-C106X60 Pressure Control Switch – Marine Refrigeration, HVAC & Compressor Protection Control

BDT 0

BD-Sensors

BDT 0

SM Marine Service

SM Marine Service

Marine Equipment Supplier

Welcome to SM Marine Service! How can we help you today? 11:05 PM
Need Help? Chat with us