G1010 Mark II
Eaton MTL (Crouse-Hinds Series)
Refurbished
| Analyser Manufacturer | Eaton – MTL, Crouse-Hinds Series |
| Analyser Model | G1010 MTL Oxygen analyser Mark II |
| Product Type | Oxygen Analyser panel (wall-mounted enclosure) |
| Display Unit | ppm (sensor cell type / range Not clearly visible in the supplied photograph) |
| Panel Items | INFLUX flowmeter (rotameter) with needle valve ("FULL OPEN"), key switch, SELECTION CAL – SAMPLE switch, CALIBRATION SPAN – ZERO switch, four tube/cable glands |
| Analyser Keys / Indicators | Edit, Up, Down, Cal; Alarm 1 and Alarm 2 LEDs |
| Panel Builder | Not clearly visible in the supplied photograph |
| Part / Serial Number, Power Rating | Not clearly visible in the supplied photograph |
| Condition | Refurbished (subject to confirmation) |
| Supplier | SM MARINE SERVICE™, Chattogram, Bangladesh |
This oxygen analyser panel is built around the Eaton MTL G1010 Mark II galvanic oxygen analyser and shows oxygen in ppm. It includes an Influx flowmeter and calibration selector switches, and is typically used to monitor oxygen in nitrogen generators and inert gas systems on ships. SM MARINE SERVICE™ (https://www.smmarineservice.com/) supplies oxygen analysers and gas analyser spares worldwide.
The MTL G1010 range uses a galvanic oxygen cell to measure oxygen from ppm to percent levels. On this panel the sample gas passes through the flowmeter to the sensor; the "SELECTION CAL – SAMPLE" switch selects calibration gas or sample, and the "CALIBRATION SPAN – ZERO" switch selects span or zero gas. The G1010 displays the oxygen value, has two alarm LEDs and keys for editing and calibration.

Eaton MTL G1010 Mark II oxygen analyser panel – SM MARINE SERVICE™
G1010 range data (Eaton catalogue):
| Measurement | Oxygen, galvanic cell |
| Cell Options / Ranges | N cell 100 ppm–50%; E cell 0.1–100%; H cell 10 ppm–10%; L cell 1 ppm–10% |
| Outputs | 0–5 V or 4–20 mA; 2 volt-free alarm contacts |
| Power | 110–120 V / 220–240 V AC 50/60 Hz or 24 V DC |
| Response (T90) | Approx. 3 s (% levels), 20 s (ppm levels) |
| Stability | <2% of reading per month or 1 ppm |
| Sample Flow | 100–300 ml/min optimum, 1000 ml/min max. |
| Ambient | 0 to +40 °C, <80% RH |
| Analyser Size | 96 x 96 x 196 mm panel mount, 1.0 kg |
| Connections | 1/4" compression fittings for 6 mm tube |
Eaton does not publish PCB numbers for the G1010. Board and cell part numbers are Not verified; send a photo of the rear label for exact matching.
Signal processing, display, alarms and outputs. PCB number: Not verified.
Consumable sensor cell – types N, E, H or L. Part number: Not verified.
AC or 24 V DC version. Part number: Not verified.
Sample gas rotameter with needle valve (Influx). Part number: Not clearly visible in the supplied photograph.

Close-up of the G1010 Mark II display and keys
Safety notes: isolate power before opening the panel. Nitrogen and inert gas can cause asphyxiation – vent sample gas safely and work with gas detection in place.
SM MARINE SERVICE™ supplies MTL G1010 analysers and complete oxygen analyser panels; availability subject to confirmation. Please send the analyser rear label photo (model code, cell type, range, supply), vessel name / IMO and delivery port. We ship worldwide.
The G1010 is a simple, stable oxygen analyser widely fitted to nitrogen and inert gas systems; a same-type replacement keeps panel cut-outs, wiring and calibration procedures unchanged.
1. What is the MTL G1010?
A galvanic oxygen analyser from Eaton MTL (Crouse-Hinds series).
2. What does this panel measure?
Oxygen in ppm.
3. Which cell types exist?
N, E, H and L cells for different ranges and background gases.
4. What outputs does it have?
0–5 V or 4–20 mA and two alarm contacts.
5. What do the switches do?
Select calibration or sample gas, and span or zero gas.
6. Do you supply G1010 PCBs or cells?
On request – send the rear label photo; PCB numbers are not public.
7. Where is it used on ships?
Nitrogen generators and inert gas systems.
8. Do you ship worldwide?
Yes.
Oxygen analyser panel with an Eaton MTL G1010 Mark II galvanic oxygen analyser (Crouse-Hinds series), reading oxygen in ppm. The wall-mounted panel includes an Influx sample flowmeter with needle valve, a key switch, a CAL / SAMPLE selector and a SPAN / ZERO calibration selector. The G1010 offers two alarm contacts, 0–5 V or 4–20 mA output and fast response, with N, E, H and L cell options. It is typically used to monitor residual oxygen in nitrogen generators and inert gas systems on tankers and gas carriers. SM MARINE SERVICE™ supplies refurbished G1010 analysers and panels worldwide.
SM MARINE SERVICE™ – Marine Automation & Navigation Equipment Supplier
Available Equipment Conditions: New • Used • Refurbished • Reconditioned (Specific product condition and availability are subject to confirmation.)
Stock Locations: Bangladesh • China
Services: Worldwide Shipping • Technical Support • Spare Parts Supply • Marine Equipment Sourcing
Samir Market, DT Road, Pahartali, beside CDA Market, Chattogram, Bangladesh
Mobile / WhatsApp / Viber: +88 01818 929292
Email: info@smmarineservice.com
Website: https://www.smmarineservice.com/
Contact SM MARINE SERVICE™ today for a quotation on the MTL G1010 oxygen analyser and gas analyser spare parts.